top of page
Integrated Surfact Technologies logo

Complete Surface Engineering

FOR ALL YOUR SCIENTIFIC, MEDICAL, AND ELECTRONIC DEVICES AND INVENTIONS

Gas-cloud_image-via_pexels-mart-production-7577792-e1638390436144.jpg

All of IST’s RPX systems employ the latest plasma technology for pre-cleaning and maximizing the number of reactive sites for modification.

Plasma

Oxidation, Hydroxylation, or Reduction

trimethylchlorosilane.png

Alter the surface characteristics with the application of silane chemicals.

Create custom surfaces with the deposition of thin ALD metal oxide films.

Modification

Silanation, Atomic Layer Deposition

IST PEGylation and Click Coatings_hero image_cdc-UBJJuAOv9os-unsplash.jpg

Terminate surfaces with the desired functionality : active adhesion (eg. amines, epoxies, azidos) or non-binding (eg. PEG’s, Perfluoronated, Akyl-groups) or bio-polymers.

Functionalize

Adhesion, Click, Bio-Polymers

You need a partner who can help you identify solutions to engineering challenges and build custom toolings just for you.

 
We offer surface-level solutions, while delivering deep customer satisfaction

At IST, we create advanced nano-coating tools for use on everything from high-volume production lines to university R&D labs. Our advanced semiconductor-style processing technology helps companies in the Life Sciences, BioMEMs and developers of new innovative devices address surface interface issues.

Whether you need a low surface energy hydrophobic coating or a high surface energy hydrophilic interface, a plasma activation to silanization or an anti-fouling coating, we can help solve your challenge.

Space | Image by Chen Liu

Our coatings have gone to outer space in high-reliability applications like the James Webb telescope camera shutters.

Why IST?

At IST, we provide a full end-to-end service, so you get a turn-key solution to nano-coating thin films.


What does that mean for you?

Shaking hands

We’re service-oriented at our core, and believe fantastic machines don’t mean much if you don’t have great people willing to stand behind them. You can have our specialists in person throughout the process and for after-sales maintenance, too.

Superior service

Read more...

Nano-Imprinting-Release-Layers.jpg

We leverage our years of experience and our propriety technology to find the right solution for your technical challenge.

Proprietary technology

Read more...

IST PEGylation and Click Coatings_hero image_cdc-UBJJuAOv9os-unsplash.jpg

Featured application

PEGylation and Click Coatings

leaf icon

PEGylation is the process of attaching the strands of the polymer PEG to molecules and surfaces.

At IST, we offer covalent attachment of various PEGs to consumables, flow cells or instruments to reduce fouling of the surfaces.

  • When would I used a Hydrophilic versus Hydrophobic coating?
    A hydrophilic coating increases the wetting on a surface. In applications like µ-fluidics or anti-fog applications, it is often desirable to a have a uniform sheet of liquid. In applications in which you want to promote cleanliness or for protection against water ingress, a hydrophobic surface property which repels the liquid is desirable.
  • What is a super-hydrophobic coating?
    When liquid interacts with a surface, it forms a “bead” with the surface. The measurement at the interface between the liquid and the surface is called the Contact Angle. A hydrophobic contact angle is typically 90° or greater and the liquid “balls-up”. A super-hydrophobic coating has a water contact angle of 150° or greater and a sliding angle of less than 10°. Most of the time, the liquid would bounce off the surface like water off a duck.
  • What effect does surface roughness have on nano-coatings?
    The surface roughness is extremely important in that it amplifies any hydrophilic or hydrophobic properties. A hydrophobic surface with surface roughness will become super-hydrophobic and vise-versa, a hydrophilic coating when deposited over a rough surface will become super-hydrophilic. Note that surface roughness can also distort visual effects like haze (like a matte finish) versus smooth (like a polished finish).
  • Are super-hydrophobic coatings durable?
    Durability has and always will be a key metric for super-hydrophobic coatings. Some degree of surface roughness is required to drive the hydrophobic property to become super-hydrophobic. However, this nano-scale roughness (typically >30nm rms) can be delicate or fragile. The mechanical durability of the rough nano-structure to abrasion is the key metric. This is usually quantified by mechanical Taber (abrasion/rubbing) testing. Note that super-hydrophobic coatings generally perform very well to liquid / non-physical contact applications.
  • How do you remove a nano-coating?
    The most effective way to remove a nano-coating is through the use of an oxidizing medium like a plasma. There are other methods including UV irradiation, ozone or caustic chemical baths.
  • How are IST’s nano-coatings applied?
    IST’s signature deposition technique is using a sub-atmospheric reactor. There are both advantages and disadvantages to the sub-atmospheric coating chamber. Advantages include complete control of the environment (ie. temperature and moisture). This means repeatability. At low pressures, the molecular mean-free path is very long which allows for the coverage into virtually any nook and cranny, down to the atomic scale. There is no chemical waste stream of organic solvents or other chemical wastes. Scale up is also possible, for business sectors, like the semiconductor IC business. The disadvantages, may be the initial capital cost of the equipment.
  • Do nano-coatings change the color of the object being coated?
    Most nano-coatings are typically 1-2nm in thickness. To visually discern any coating, the thickness needs to be around a quarter (¼λ) wavelength of light which essentially means that thicknesses under 100nm are invisible.
  • Are IST’s nano-coatings REACH/RoHS compliant?
    At IST, we do numerous types of coatings for various applications. The chemicals used by 100% RoHs compliant. We have coatings which are also 100% REACH compliant.
  • Are nano-coating Bio-compatible?
    IST has tested most of our coatings per the FDA ISO:10993 Biocompatibility guidelines for Surface Devices. This includes Cytotoxicity, Sensitization and Irritation/Intracutaneous effects.
  • Are nano-coatings Electrically Conductive?
    Nano-coatings are intrinsically non-conductive. However, at the thicknesses being deposited of several nanometers, they have no effect on the electrical conductivity. Another way to view this, any nanometer film <15nm can be viewed as being non-contiguous so electrical conduction is not impeded.
  • Can you rework nano-coatings?
    Yes. The nano-coating can be stripped using a plasma and then reapplied. Also, there are many films which can be classified as SAM’s (Self Assembling Monolayers). These SAM films are self-limiting so you cannot over deposit these coating as well.
  • What is the lifetime of a nano-coating?
    The coating should last the lifetime of your device or coated substrate. Our coatings which are chemically inert like most hydrophobic films will last the lifetime of the device, unless intentionally destroyed by a plasma or UV or ozone exposure.
  • Are nano-coatings safe for the environment?
    IST’s nano-coating are completely safe for the environment. Most of the time, all reaction by-products are also destroyed by a plasma cleaning. With the IST sub-atmospheric process, there is no wet chemical waste stream of solvents.
  • Are IST’s coatings TSCA approved and regulated?
    The EU has a mandatory phaseout of PFOA’s (Perfluorooctanoic acid) for most manufacturing applications to prevent the accumulation of “Teflon like” byproducts in the environment. While there are many PFOA chemicals which have desirable properties (ie. contact angle), IST has alternative non-PFOA coatings which meet or exceed the user’s specifications. Many of the chemicals used are TSCA approved.
  • How can you tell if there is a nano-coating present or effective?
    Depending on the nano-coating, there is a measurable surface energy associated with the coating. This characteristic energy is measured using a Goniometer. Generally, the film is wetted with a small droplet of a known liquid and how this liquid interacts with the surface (i.e., the contact angle) is measured. As an example, if the contact angle for a water droplet measures 108°, then one would conclude the hydrophobic coating is still present. Reactive films like epoxies or amine’s or HMDS have characteristic angles like 63°, 70° etc. so a good indication of the coating can be derived.
  • Is surface preparation before coating important?
    Yes. Most nano-coating are only several molecules thick. A greasy fingerprint will be orders of magnitude thicker than most targeted coatings. Cleaning of the samples prior to nano-coatings is very important. Most of the time, a solution rinse is used ranging from a piranha acid bath or alcohol depending on the articles. Immediately prior to any nano-coating, a plasma clean pretreatment is usually performed.
  • Can you pattern a nano-coating?
    Yes and No. Selective patterning of a nano-coating can be performed and dependent on the coating to be applied and the article to be coated. This is often referred to as Selective Deposition. There are many other methods as well. In a process called “Lift-Off”, a mask is applied (eg. resist, tape) to selective areas and following the coating the mask is removed along with any coating deposited on the masking material. However, since the nano-coating process is sub-atmospheric, a mask with intimate contact with the substrate is needed.
  • What type of metrology tools do you use on nano-coatings?
    Due to the extreme thinness of the coating, metrology is specialized. A goniometer is used to measure the surface energy. An ellipsometer is often used to measure the thickness of the film but a known reference material is required. For example, a piece of polished silicon will be deposited adjacent to the real articles as a witness and then measured. An AFM (Atomic Force Microscope) can measure the height and density of the nanocoating. XPS (Photo-electron spectroscopy) can measure the chemical surface elements and concentration. As a last resort, IST has collaborated with NIST to use their synchrotron-based near edge x-ray absorption fine structure (NEXAFS) spectroscopy tool to measure the surface orientation of the deposited molecules. (Contact IST for more discussions on NEXAFS.)
  • Are nano-coatings chemical resistant?
    Chemical resistance depends on number of factors. One class of hydrophobic coatings are perfluorinated which is like a “Teflon”. These files are very chemically inert to organic solvents, alcohols and general household cleaners. These are also hydrophobic in nature which can provide water resistance.
  • Can I make solder connections when the part has been nano-coated?
    Once a substrate is hydrophobic nano-coated, soldering can be troublesome since the flux may not wet the surfaces to be joined. With some practice, the nano-coating can be disrupted, and normal soldering can be performed.
  • What is IST’s “Repellix” nano-coating?
    Repellix is IST patented nano-composite film which is an aluminum oxide super-hydrophobic coating. Repellix offers superior protection against liquids and is oleophobic against substances like Cerumen (ear wax).
  • I have specific questions regarding my application and not sure if a nano-coating will work. Can I get help?
    Please contact us at IST. We have years of experience and will be glad to investigate collaboration with you. email: info@insurftech.com Phone: +1-650-324-1824
Leaf with water droplets_pexels-egor-kamelev-785695.jpg

The IST process

leaf icon

Creating custom solutions for your unique nano-coating needs

Let’s engineer something better, together.

IST Contact Angle Meter

Integrated Surface Technologies

ADVANCED NANO-COATINGS FOR A GREENER WORLD

bottom of page